Tempér. | Dureté | ILO | Temp. de fragilité | Rouge Congo | Caract. principale | Applications | |
ISO868 | ISO4589 | ISO-R182-1 | |||||
°C | Shore | % | °C | min. | |||
VEIP217 | 85 | 50A 55A 65A | >18 | -30 | Résistance hydrocarbure | Auto - Surmoulage passe câble | |
VEEC455 | 105 | 78A | >18 | 130 | Ignifugé Résistance à l'huile | CNOMO | |
VEC4418 | 85 | 80A 90A | >18 | >100 | Mine - Machinerie | ||
VEC4597 | 85 | 80A | >20 | >60 | Ignifugé Résistance à l'huile | Machinerie | |
VEC4603 | 125 | 75A 80A | >18 | 240 | Ignifugé | ||
MEC4599 | 85 | 80A 90A | >18 | -40 | 160 | Gainage | Auto T1 - Type A |
MEEC296 | 105 | 84A 90A | >18 | -40 | >100 | Tube de guidage/gaine | Auto T2 - Type B |
MEEC280 | 105 | 43D | >18 | -40 | >180 | Isolation | Auto T2 - Type B |
MEEC282 | 105 | 47D | >18 | -40 | >180 | Isolation | Auto T2 - Type B |
MEEC274 | 125 | 47D | >18 | -40 | >240 | Isolation | Auto T3 - Type C |
MEEC278 | 125 | 80A 85A | >18 | -40 | >240 | Gainage | Auto T3 - Type C |
MEC4627 | 125 | 85A | 28 | >240 | Forte résistivité - Ignifugé | Sous marin |
Les propriétés indiquées sont typiques mais ne doivent pas être considérées comme des spécifications.
Tous les grades ne sont pas disponibles dans toutes les régions. Merci de contacter votre représentant local.
Depuis Juin 2016 la marque mondiale pour les compounds vinyliques destinés à la câblerie et filerie est :
- VINIKA™: compounds flexibles PVC-P